$179.95 Canadian (approx. $124 U.S.)
plus applicable taxes, shipping & handling
Features
DC Voltage
| Range | Resolution | Accuracy | Input Impedance | Overload Protection |
|---|---|---|---|---|
| 400 mV 4 v 40 V 400 V 1000 V |
100 uV 1 mV 10 mV 100 mV 1 V |
+/-(0.5%rdg + 1 dgt) | .GT. 100 Megohm 11 Megohm 10 Megohm 10 Megohm 10 Megohm |
DC 1100 V AC 800 V |
AC Voltage
| Range | Resolution | Accuracy | Input Impedance | Frequency Response | Overload Protection |
|---|---|---|---|---|---|
| 400 mV 4 V 40 V 400 V 750V |
100 uV 1 mV 10 mV 100 mV 1 V |
+/-(1.2% rdg + 3dgts) (750V range +5 dgts) |
.GT. 100 Megohm 11 Megohm 10 Megohm 10 Megohm 10 Megohm |
50 / 60 Hz 40 Hz to 500 Hz 40 hz to 500 Hz 40 Hz to 500 Hz 40 Hz to 500 Hz |
DC 1100 V AC 800 V |
DC Current
| Range | Resolution | Accuracy | Input protection | Burden Voltage |
|---|---|---|---|---|
| 40 mA 400 mA 20 A |
10 uA 100 uA 10 mA |
+/-(1% rdg + 1 dgt) (20 A +/- 5% rdg + 2 dgts) |
0.5 A / 250 V fuse 0.5 A / 250 V fuse 20 A 600 V high energy fuse |
0.45 V 1.5 V 1.3 V |
AC Current
| Range | Resolution | Frequency Response | Accuracy | Input Protection | Burden Voltage |
|---|---|---|---|---|---|
| 40 mA 400 mA 20 A |
10 uA 100 uA 10 mA |
40 Hz to 500 Hz | +/-(1.5%rdg + 3 dgts) (20 A +/-2% rdg + 5 dgts) |
0.5A 250 V fuse 0.5A 250 V fuse 20 A 600 V high energy fuse |
0.45 V 1.5 V 1.3 V |
Audible Continuity
| Range | Resolution | Open Circuit Voltage | Continuity Beeper | Overload Protection |
|---|---|---|---|---|
| Audible Continuity | 0.1 ohm | .LE.0.5 V | .LE. approx. 40 ohms | 350 Vrms |
Diode Test
| Range | Resolution | Short Cct. Current | Accuracy | Open Cct. Voltage | Overload Protection |
|---|---|---|---|---|---|
| Diode Test | 1 mV | 0.8 mA typical | +/-(1% rdg + 2 dgts) | 3 V | 350 Vrms |
Capacitance ( Cx )
| Range | Resolution | Accuracy |
|---|---|---|
| 4 nF 40 nF 400 nF 4 uF 40 uF |
1 pF 10 pF 100 pF 1 nF 10 nF |
+/-(1.5% rdg + 20 dgt) +/-(1.5% rdg + 10 dgt) +/-(1.5% rdg + 10 dgt) +/-(1.5% rdg + 10 dgt) +/-(1.5% rdg + 10 dgt) |
Resistance
| Range | Resolution | Accuracy | Open Circuit Voltage | Overload Protection |
|---|---|---|---|---|
| 400 ohm 4 kohm 40 kohm 400 kohm 4 Megohm 40 Megohm |
0.1 ohm 1 ohm 10 ohm 100 ohm 1 kohm 10 kohm |
+/-(0.75% rdg + 3 dgts) +/-(0.75% rdg + 3 dgts) +/-(0.75% rdg + 3 dgts) +/-(0.75% rdg + 3 dgts) +/-(0.75% rdg + 3 dgts) +/-(1.5% rdg + 5 dgts) |
.LE. 0.5 V | 350 Vrms |
Frequency
| Range | Resolution | Accuracy | Sensitivity |
|---|---|---|---|
| 100 Hz 1 kHz 10 kHz 100 kHz 500 kHz |
0.01 Hz 0.1 Hz 1 Hz 10 Hz 100 Hz |
+/-(0.1% rdg + 2 dgts) | 100 mV / 1 V / 10 V (by Range Button Selector) |
When we asked our supplier for a multimeter, we asked for a Fluke 87 or better. They sent us two TES 2610. We played with it for a few days, and decided it was worth a serious test, so we gave one to a local hi-tech firm to test. They liked it so much, they kept it. The other one is still in abuse here - this is the meter to buy if you want quality and value.
21 Market ST. N., PO
Box 606, Smith Falls, Ont. K7A 4T6, Canada
Tel: (613) 283-5195 Fax: (613) 283-0637
Email: rftech@falls.igs.net
© 3125661 Canada Inc.