MIC-1028
REDUCED Canadian (approx. $120
U.S.)
Specifications
Input Sensitivity (typical)
- Input Amplifier Setting = 50 ohms, VSWR « 2:1
- ......................Range = 1 MHz to 2.8 GHz
- Sensitivity (typical)
- ...« 1.5 mV...@...100 MHz
- ...« 5 mV......@...250 MHz
- ...« 5 mV......@...1 GHz
- ..« 100 mV...@...2.4 GHz
- Input Amplifier Setting = 1 MegOhm
- ......................Range = 10 Hz to 50 MHz
- Sensitivity (typical)
- « 10 mV for 10 Hz to 10 MHz
- « 20 mV for 10 MHz to 50 MHz
Frequency Display Resolution
- Range Setting.....Gate Time Selected.....Last
Significant Digit
- .....250 MHz...............0.0625
sec.................10 Hz
- .................................0.25
sec.....................1 Hz
- .................................1
sec.........................1 Hz
- .................................4
sec........................0.1 Hz
- ..........................................................................
- .....2.8 GHz..................O.0625
sec..............1000 Hz
- ...................................0.25
sec...................100 Hz
- ...................................1
sec.........................10 Hz
- ...................................4
sec.........................10 Hz
BarGraph Display of RF Signal Stength
- Frequency.....1st Segment.....full scale (16
segments)
- 27 MHz.................7 mV...........100 mV
- 150 MHz...............5 mV............90 mV
- 800 MHz..............10 mV.........200 mV
Physical Characteristics
- Multi-Function - Frequency, Period, Auto Trigger
& Hold
- Dual 50 ohm / 1 MegOhm inputs, standard BNC
connector
- High Speed 250 MHz Direct Count for High
Resolution
- Switchable Backlight to light up Display in poor
light conditions
- Hold Switch locks readings
- 6 hour NiCad operation with low battery indicator
- extruded aluminum cabinet
- 10 digit LCD display
- 105mm h x 68mm w x 32mm d, weight = 220 grams
- timebase « 1 PPM (typical at room temp)
- includes extendable antenna
|
Covered by One Year limited Warranty
When we first tested this counter, we used and abused it
for a full month before listing it. We baked it in the oven for 4
hours, stuck it in the fridge, and sat it beside a Fluke 7261
precision benchtop counter, and the Optoelectronics Scout for 10
hours continuous. It exceeded all of our expectations - not only
did it retain accuracy but it proved to be rugged and reliable. 3
years later we are still using this counter for demonstrations
and around the shop.